8-6 Troubleshooting AlphaServer 1000A Owner's Guide
The kill and kill_diags Commands
The
kill
and
kill_diags
commands terminate diagnostics that are currently
executing.
The
kill
command terminates a specified process.
The
kill_diags
command terminates all diagnostics.
Note: A serial loopback connector (12-27351-01)
must be installed on the COM2 serial port for the
kill_diags command to successfully terminate system
tests.
The show_status Command
The
show_status
command reports one line of information per executing
diagnostic. Many of the diagnostic tests are run in the background and provide
information only if an error occurs. Use the
show_status
command to display the
progress of the diagnostics.