Seitenansicht 19
Check that the COURTESY LIGHT SWITCH
function of the Wall Push-Button is operating
correctly.
With the door in the closed position, press the
button marked "LIGHT" on the Wall Push-
Button Console. The operator's courtesy light
should switch "on" without the door being
activated. The courtesy light should switch
itself "off" automatically after 3 to 4 minutes.
10.3 TESTING THE OPERATOR'S
COURTESY LIGHT
THE "SAFETY OVERLOAD" FEATURE
will be automatically activated when ....
If closed, ..... the door will open, and
the courtesy light will
switch "ON".
If open, ....... the door will close!
If opening, ( still in motion ), ......
.... the door will stop!
If closing, ( still in motion ), ......
..... the door will stop!
PRESSING THE "DOOR" BUTTON
ONCE.........
SECTION 11
OPERATOR FUNCTIONS
An obstruction is encountered by the
door whilst it is opening, ........
....... the door will stop!!!
Take Note:- ...
The door will not reverse its direction
whilst it is in the "opening mode". ....
......... It will stop!!!
An obstruction is encountered by the
door whilst it is closing, ......
....... the door will first stop and
then automatically reverse it's
direction and move to the "full-open"
position.
1 The door should open to its proper height
as specified.
2 Door closes completely without imposing
undue strain on the operator.
3 Overload sensitivity is properly set for both
opening and closing modes, { i.e. safety
reverse function }.
4 If the door strikes an obstruction whilst in
the "closing mode", it should first stop
and then automatically reverse its
direction to the "full-open" position.
5 In the "opening mode" the door must
come to a complete stop should it strike an
obstruction.
6 The Emergency Manual Release
Mechanism functions correctly with the
door in both the open and closed
positions.
7 The Courtesy Light timer is operative.
8 The Radio Controls and Push-Button
function properly.
9 CYCLE TIMES :-
SECTIONAL DOORS
....... approx. 18 sec.
TIP-UP DOORS ( Pantograph type ).
....... approx. 9 sec.
STEEL ROLL-UP DOORS
....... approx. 16 seconds.
10.4 OPERATOR PERFORMANCE
CHECKS
CHECK THE FOLLOWING:-
MAN 01 - page 19 Version 5
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 32 33

Kommentare zu diesen Handbüchern