30
FAN BELT REMOVAL AND REPLACEMENT
The Ecogrinder incorporates two drive fan belts (an inner and an outer) to power the fan
assembly. If the unit is not removing the dust, you will need to inspect the fan belts, fan
assembly,anddustbagtondthecauseoftheproblem.
NOTE:ThisEcogrindermakesuseofaatfanbeltandpulleysystemthatisself-centering
due to the barrel shape of the pulleys. If the fan belt is worn or dirty it can rotate off
the pulleys, this will be indicated by a loss of suction.
TESTING THE UNIT FOR FLOW
1. A simple test can be done to see if the fan unit is working correctly.
2. Disconnectthehoseandback-owpreventerfromthetoolandstandthegrinderup
so it is resting on the protective housing and the top handle. Point the fan exhaust in
a direction away from you or anyone else.
3. Turn the unit on and hold a piece of paper over the exhaust port. Paper should extend
and stand up straight when unit is turned on.
..
4. Ifthetestindicatesaweakornoowcondition,thefanbelts,pulleys,andfanunitwill
needtobecheckedtondthecauseoftheproblem.
Figure-33
Figure-34
Fan Unit Test
OFF ON