Alpha ECG-125 Bedienerhandbuch Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
21
3. Using small needle nose pliers, gently pull the carbon brush holder straight out from
the motor housing. After removing the carbon brush holder from the motor housing,
you need to remove the power wire terminal from the carbon brush holder (Note: the
path of the wire, as it is important for reassembly of the unit). The carbon brush holder
assembly is now free from the machine and can be inspected.
4. Pictured on the left below, is a worn carbon brush in the holder (Note: the twisted wire
isattheendoftheslotandthecarbonbrushisalmostushwithholder).Ontheright
below, is a new carbon brush in the holder.
NOTE: Carbon brushes sometime wear at different rates; however, both carbon brushes
should be replaced at the same time. The carbon brushes in this grinder are located
under the rear handle.
WARNING!
Replacing the carbon brushes in this unit with non-Alpha
®
parts could damage the unit,
and will void the warranty.
Power Wire
and Terminal
Figure-15
Figure-16
Carbon Brush Removal
Worn and New Carbon Brushes
Worn
New
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 47 48

Kommentare zu diesen Handbüchern

Keine Kommentare